Victron charge controller MPPT BlueSolar 75/15 - 12V / 24V 15A
- Ultrafast Tracking Maximum Power Point Tracking (MPPT, for its acronym in English)
- Electronic components encapsulated in resin to protect electronic components from the elements.
- BatteryLife: Intelligent battery management
When a solar charge controller is not able to recharge the battery to full capacity in a day, what happens is that the battery cycle continuously changes between states "partial charge" and "discharge end." This mode of operation (no regular full recharge) destroy a lead-acid battery in weeks or months.
BatteryLife The algorithm monitors the state of charge of the battery and increases slightly from day to day, the level of load shedding up to the absorption voltage. From that point, the level of load shedding is modulated so as to reach the absorption voltage aa about once a week.
The MPPT 75/15 can also be configured to keep the load control mode traditional disconnection with a fixed voltage.
The output load is short circuit proof and can provide capacitive loads such as an inverter.
Electronic components encapsulated in resin
- Protects electronic components from the elements
Automatic recognition of the battery voltage
- The MPPT 75/15 system automatically adjusts to 12 or 24 V.
BlueSolar MPPT charge controller 75/15
- Battery voltage V AutoSelect 12/24
- Maximum battery current 15 A
- Maximum PV power, 12V 1a, b) 200 W (MPPT range 15 V and 70 V respectively 95 V)
- Maximum PV power, 24V 1a, b) 400 W (MPPT range 30 V and 70 V respectively 95 V)
- Automatic load shedding Yes, maximum load 15 A
- Maximum open circuit voltage of 75 V FV
- Maximum efficiency 98%
- Internal consumption 10 mA
- Charging voltage "absorption" 14.4 V / 28.8 V
- Floating charge voltage 13.8 V / 27.6 V
- Variable loading algorithm multistage
- Temperature compensation -16 mV / ° C resp. -32 MV / ° C
- Continuous load current crest 15A
Disconnect low voltage load
- 11.1 V / 22.2 V or 11.8 V / 23.6 V
- or algorithm BatteryLife
Reconnecting low voltage load
- 13.1 V / 26.2 V or 14 V / 28 V
- or algorithm BatteryLife
Protection
- Battery reverse polarity (fuse)
- Output short circuit
- Overtemperature
Puerto data communication
- VE.Direct, see the white paper on data communication on our website
Operating temperature -30 to +60 ° C (full rated power up to 40 ° C)
100% relative humidity, noncondensing
HOUSING
- Blue (RAL 5012)
- Terminals 6 mm ² / AWG10
- Degree of protection IP43 (electronic components) IP22 (connection area)
- Weight 0.5 kg
- Dimensions (H x W x D) 100 x 113 x 40 mm.
1a) If there is excess PV power, the controller will limit the power input 200W resp. 400W
1b) the PV voltage must exceed the Vbat (battery voltage) 5V to boot the controller. Once started, the PV voltage min. is Vbat + 1V